  Multi-Core Round Fiber Optic Ribbon Cable II  
     
     
 
 

Features

 
  - Good mechanical and environmental characteristics.  
  - Flame retardant characteristics meet the requirements of relevant standards.  
  - The mechanical and physical characteristics of the outer jacket meet the requirement of relevant standards.  
  - Soft, flexible and easy to do stripping, splicing and cabling.  
 

Availabilities

 
  - Fiber ribbon layer count: 2 ~ 12; fiber count per fiber ribbon: 2, 4, 6, 8, 12; or customized.  
  - Types of fiber: G.652 A/B/C/D or G.655 A/B/C singlemode optic fiber; OM1, OM2 or OM3 multimode optic fiber, or other types of optic fiber.  
  - Material of jacket: Flame retardant polyvinyl chloride (PVC); low smoke zero halogen (LSZH) flame retardant polyolefin; thermoplastic polyurethane (TPU); environmental materials and mouse-proof materials are also used where there are environmental or special requirements; or other customized material.  
  - Loose tube material is usually poly butylenes terephthalate (PBT).  
  - Color of jacket and fiber meets the requirements of relevant standards, or customized color.  
  - Cable dimension: the nominal diameter, or customized dimension.  
  - Delivery length: 1km or 2km or customized length.  
 

Applications

 
  - Indoor cabling; building access.  
  - Interconnection of fiber optic equipments.  
  - Used in pigtails and patch cords.  
 
  Specifications  
 
Fiber
Count

Fiber Ribbon Layer Count

Fiber Count Per Ribbon

Nominal
Outer Dia.
(mm)
Weight
(kg/km)
Tension
(N)
Crush
(N/100mm)
Min. Bend Radius
(mm)
Temperature Range
(≧)
Long Term
Short Term
Long Term
Short Term
Dynamic
Static
16 4 4 6.2 36.0 200 660 200 1000 20 D 10 D -20 to +60
36 6 6 7.6 66.0 200 660 200 1000 20 D 10 D
64 8 8 9.6 88.0 200 660 200 1000 20 D 10 D
144 12 12 12.5 190.0 200 660 200 1000 20 D 10 D
 Note: 1. All the values in the table, which are for reference only, are subject to change without notice;

           2. Tension and crush values provided in the table are all minimum values. .

         3. D means the outer diameter of the whole round cable.