  Multi-Core Round Breakout Indoor Fiber Optic Cable III  
     
     
 
 

Features

 
  - Good mechanical and environmental characteristics.  
  - Flame retardant characteristics meet the requirements of relevant standards.  
  - The mechanical and physical characteristics of the outer jacket meet the requirement of relevant standards.  
  - Soft, flexible and easy to do stripping, splicing and cabling.  
 

Availabilities

 
  - Subunit count: 2, 4, 6, 8, 10, 12; fiber count per subunit: 4, 6, 8, 12; or customized.  
  - Types of fiber: G.652 A/B/C/D or G.655 A/B/C singlemode optic fiber; OM1, OM2 or OM3 multimode optic fiber, or other types of optic fiber.  
  - Material of jacket: Flame retardant polyvinyl chloride (PVC); low smoke zero halogen (LSZH) flame retardant polyolefin; thermoplastic polyurethane (TPU); environmental materials and mouse-proof materials are also used where there are environmental or special requirements; or other customized material.  
  - Color of jacket and fiber meets the requirements of relevant standards, or customized color.  
  - Cable dimension: the nominal diameter, or customized dimension.  
  - Delivery length: 1km or 2km or customized length.  
 

Applications

 
  - Indoor cabling as branch cable; building access.  
  - Interconnection of fiber optic equipments.  
 
  Specifications  
 
Fiber
Count

Subunit Count

Fiber Count Per Subunit

Nominal
Outer Dia.
(mm)
Weight
(kg/km)
Tension
(N)
Crush
(N/100mm)
Min. Bend Radius
(mm)
Temperature Range
(≧)
Long Term
Short Term
Long Term
Short Term
Dynamic
Static
16 4 4 18.0 253.0 400 1320 300 1000 20 D 10 D -20 to +60
24 4 6 21.5 400.0 500 1600 300 1000 20 D 10 D
36 6 25.6 528.0 600 1600 300 1000 20 D 10 D
48 8 30.0 960.0 600 1600 300 1000 20 D 10 D
64 8 8 34.5 1100.0 700 2000 300 1000 20 D 10 D
72 6 12 38.0 1295.0 800 2000 300 1000 20 D 10 D
 Note: 1. All the values in the table, which are for reference only, are subject to change without notice;

           2. Tension and crush values provided in the table are all minimum values. .

         3. The values of cable dimension and weight are based on single core cable with 2.0mm outer diameter.

           4. D means the outer diameter of the whole round cable.